Short Range Sensor

Summary

The Short Range Sensor activates TraffiCalm flashing crossing systems when motion occurs within a defined approach area. The device monitors the sidewalk or trail approach and sends an activation signal to the controller through a contact-closure input.

The sensor operates automatically and does not require push-button interaction. Event-based activation reduces unnecessary flashing operation and lowers system power usage compared to continuously operating warning devices.

Specifications

Detection

Doppler microwave motion sensing
Operating frequency
24 GHz band
Detection modes
approach, depart, or bi-directional
Typical detection range
Up to approximately 60 ft (human-scale movement)
Typical detection range
Up to approximately 80 ft (bicycle or larger movement)
Beam angle
~18° horizontal, ~9° vertical
Typical response time
0.2 seconds

Electrical Interface

Operating voltage
12–24 VAC or DC
Current consumption
~75 mA
Output
relay contact closure
Contact type
Form A (Normally-Open)
Interface
dry contact activation input
Isolation
no voltage provided by the sensor

Compatibility

Compatible with TraffiCalm flashing sign controllers
Functions as a standard activation input device

Environmental

Outdoor field device enclosure
Operating temperature
−35 °F to 165 °F (−37 °C to +75 °C)

Physical Description

Pole-mount bracket
Dimensions
approximately 7.5 in × 6 in × 5.5 in
Weight
approximately 1.55 lb
Integrated 15 ft harness
Recommended mounting height: 10–20 ft above grade

Adjustable Parameters

Detection range
Detection direction (approach / depart / bi-directional)
Relay hold time (0.25–25 seconds)

Warranty

5-year limited warranty
Unlimited U.S.-based technical support

LED Flashing Rings

Yield

Chevron

Rectangle

School Zone

Warning

Stop

Railroad

  • M75-R3030-BA44

    30" Railroad Crossing Advanced Warning PlateAmber

    Factory installed to W10-1 Static Sign

  • M75-R3636-BA44

    36" Railroad Crossing Advanced Warning PlateAmber

    Factory installed to W10-1 Static Sign

  • M75-R4848-BA44

    48" Railroad Crossing Advanced Warning PlateAmber

    Factory installed to W10-1 Static Sign

Controllers & Collaborators

CTL2 Series

CTL3 Series

AC Power Systems

E-Series

S-Series

T-Series

W-Series

Speed Compliance

Flashing Sign Systems

Flashing Sign System Solar Kits